User`s manual

5White-Balance Adjustment
5-1 Equipments list
Chroma7100 1set
VG828 video signal generator 1set
Chroma-2326 1set
5-2 Preparation and Adjustment process
1 Preparation:
z Connect rear Video port of PDP with AV port of VG-828.
z Connect component port of PDP with YPbPr port of VG-828
z Connect VGA port of PDP with corresponding port of Chrom2326
z Turn power of PDP and test instrument on.
z Before open lens, Press O-CAL of Chrom-7100 and revise lens.
2Adjustment process
AV Adjustment
1). Change to Video mode, you can press “SOURCE” of remote. Press “Vol - ”, adjust volume
until Min. Then press number key “6543”and enter factory Menu.
2). Press “SOURCE” and change to Video Rear mode
3). When setting of VG-828 is TIM946/PAT922, 32 Gray steps. Then, see the color of picture
is deflection or not. And the Gray steps distinguish 28 steps from 32steps or not.
. If dark of Gray is deflection, press “CH+/-”and adjust:
1.White.BRoCVBS (vMin=0,vMax=100,vDef=50) 50,
2.White.BBoCVBS (vMin=0,vMax=100,vDef=50) 50,
3.White.BGoCVBS (vMin=0,vMax=100,vDef=50) 50,
. If sharpness of Gray is deflection, press “CH+/-”and adjust:
4.White.BRgCVBS (vMin=0,vMax=100,vDef=50) 50,
5.White.BBgCVBS (vMin=0,vMax=100,vDef=50) 50,
4). When the Gray is ok, change input signal to white picture at P936, Use colored analysis
instrument Chroma7100 measure colors temperature value of picture at present (whether
Chroma7100 is it given to picture center to pop one's head), On pressing the remote
controller such as the specification of going beyond "program + /- "key choose following
the projects adjust
4.White.BRgCVBS (vMin=0,vMax=100,vDef=50) 50,
5.White.BBgCVBS (vMin=0,vMax=100,vDef=50) 50,
Page 25 of 83