Specification Sheet

Page 1 of 6
AOSCG10210
Commercial Gas
Water Heaters
© April 2017 A. O. Smith Corporation. All Rights Reserved
www.hotwater.com | 800-527-1953 Toll-Free USA | A. O. Smith Corporation | 500 Tennessee Waltz Parkway | Ashland City, TN 37015
INTELLIGENT CONTROL SYSTEM
WITH LCD DISPLAY AND iCOMM
CONNECTIVITY
Exclusive A. O. Smith designed touch display
control system
Provides detailed water heater status
information
Precise temperature control adjustable from 90
to 180 degrees
Built-in diagnostics
Run history information
Cyclone
®
Mxi Modulating water heaters
are compatible with the iCOMM
remote
monitoring system. Call 1.888.928.3702 for
information.
COMING SPRING 2017
Remote monitoring capability utilizing the
iCOMM app. Wi-Fi connectivity kit requited for
models 120-250, standard on models 300-500.
SUBMERGED COMBUSTION CHAMBER,
WITH HELICAL HEAT EXCHANGER COIL
Positioned in center of tank, surrounded by
water to virtually eliminate radiant heat loss
from chamber
Direct spark ignition
Spiral heat exchanger keeps hot burner gases
swirling, uses centrifugal force to maximize
efficiency of heat transfer to water in tank
Spiral heat exchanger reduces lime scale
from forming on water-side surfaces, which
maintains energy efficiency over time
POWERED ANODES STANDARD ON ALL
MODELS
Provides long-lasting tank protection in varying
water conditions
Powered anodes are non-sacrificial
Automatically adjusts output needed to
properly protect the tank
CYCLONE
®
Mxi MODULATING
MODULATING BURNER ADVANCES THE CYCLONE TO HIGHER LEVELS OF EFFICIENCY
The full line of A. O. Smith Cyclone Mxi condensing water heaters has been designed to provide
years of dependable service and feature industry leading technology. Models are available from
120,000 to 500,000 Btu/h and all deliver thermal efficiencies of 95% and higher. The unique helical
coil heat exchanger limits weld joints for optimal service life while maximizing heat transfer.
Cyclone is the industry leader in high efficiency commercial water heating. The current Mxi
modulating models adjust firing rate to the specific demand further increasing efficiency and
money savings.
PERMAGLAS
®
ULTRA COAT
GLASS
LINING
Glass coating is applied using a liquid slush
coating technique to ensure uniform coating
Heat exchanger coil is glassed both externally
and internally for optimum protection
MECHANICAL VENTING VERSATILITY
Conventional power venting or direct venting
Vents vertically or through a sidewall
Front located exhaust and condensate
connections allow for easy install and access
Vents with low cost PVC Schedule 40 intake
and exhaust pipe. Approved for optional CPVC
Schedule 40, Polypropylene and AL29-4C
stainless steel vent materials
Direct-vent intake and exhaust pipe can
terminate separately outside building or
through single opening, using concentric vent
assembly
Canadian installations require ULC S636 PVC/
CPVC, ULC S636 Polypropylene and AL29-4C
stainless steel pipe for intake and exhaust
HIGH EFFICIENCY MODULATING PRE-
MIX POWERED BURNER
Down-fired pre-mix burner provides optimum
efficiency and quiet operation
Top-mounted burner position prevents
condensation from affecting burner operation
3-YEAR LIMITED TANK / 1-YEAR
LIMITED PARTS WARRANTY
For complete warranty information, consult
written warranty or go to hotwater.com.
BTH-120(A) THROUGH BTH-500(A)
MODEL SHOWN:
BTH-199(A) SERIES 300/301

Summary of content (6 pages)