Brochure

20
Power Burner Water
Heaters Conservationist
®
Models
Power burner models provide
thermal efficiencies of 80%
These gas power burner models provide an outstanding thermal
efciency of 80% or more and are suitable for commercial applications.
Small Volume BTP Quality Features:
UL listed power burner
ASME construction
CSA Certified and ASME rated T&P relief valve
Handhole cleanout(s) for easy maintenance
Three-year limited tank warranty
Fully automatic controls ensure safe, efficient operation
Barometric draft damper ensures correct airflow in the vent
Factory Start-up Included, required for activating warranty and assuring
quality performance
Mounted on rugged channel iron skids for easy transport during
installation
Multiple anodes for extra protection against tank corrosion
Flame inspection port opening for visual inspection of flame
characteristics during operation
Spark pilot ignition
Factory-installed burner for easy installation
Complies with SCAQMD rule 1146.2 and other Air Quality Management
Districts with similar requirements for
low NOx emissions
Meets the Thermal efficiency and standby loss requirements of the U.S.
Department of Energy and current edition of ASHRAE/IESNA90.1
Contact Canadian customer service for availability in Canada
3-year limited tank warranty
Options (Not Available On All Models)
5-year limited tank warranty
3 vent options: atmospheric, sidewall and direct vent
Shown here is the power burner combustion chamber used in the BTP-540A, BTP-650A
& BTP-740A models. These models can vent through a side wall up to 100 ft. without
an external blower.
1. Exclusive PermaGlas
®
Ultra Coat
Glasslined Tank protects tank surfaces and all
welds from the corrosive effects of hot water.
2. Proylite 3100 Chamber Wall retains heat, ensuring cool operation and maximum
heat transfer to water, not the room.
3. Premix Combustion System provides super clean low-NOx flame. Helps eliminate hot
spots and uneven heat transfer.
4. Sealed Combustion Chamber reduces heat loss.
FIRST RECOVERY INPUT APPROX
MODEL GAL. HOUR CAPACITY/GPH VENT BTU/HR. HT. DIA. SHIP
NO.+ CAP. DELIVERY 100°F RISE SIZE
NATURAL GAS WEIGHT
RATING
BTP-139 86 196 136 6 140,000 74 3/4 27 3/4 556
BTP-199 86 253 193 6 199,000 74 3/4 27 3/4 545
BTP-270 86 268 262 8 270,000 74 3/4 27 3/4 547
BTP-370 75 412 359 8 370,000* 74 3/4 27 3/4 634
BTP-139A 86 196 136 6 140,000 74 3/4 27 3/4 658
BTP-199A 86 253 193 6 199,000 74 3/4 27 3/4 635
BTP-270A 86 322 262 8 270,000 74 3/4 27 3/4 632
BTP-370A 75 412 359 8 370,000* 74 3/4 27 3/4 731
BTP(V)-540A* 85 583 523 9 540,000 93 29 1/2 950
BTP(V)-650A* 85 690 630 9 650,000 93 29 1/2 950
BTP(V)-740A* 85 778 718 9 740,000 93 29 1/2 950
All dimensions in inches
Complies with
Standard on
BTPN-140 thru
500, 540, 650
& 700 models
(BTPN & BTPV
Models only)
(BTP(V)-540
thru BTP(V)-
740 Models
*Available with optional horizontal sidewall or sealed direct vent
termination kits (specified at time of order).
+After January 1, 2012, Models will not meet SCAQMD Rule 1146.2 requirements for
low NOx emissions.
AOSCA80000 R Oct 2011 Com Catalog:108078_ResidentialFul#7A635.qxd 10/28/11 5:51 PM Page 20