Brochure

14
Cyclone
®
Xi BTH and
BTX Gas Models
Up to 96% thermal efficiency,
venting exibility, outstanding value
The A. O. Smith Cyclone Xi is the industry’s most technologically
advanced commercial water heater. The BTH-300, BTH-400 and
BTH-500 models take Cyclone Xi performance to the highest
levels, with up to 96% thermal efficiency, a 130-gallon storage
tank, and inputs of 300,000, 400,000 and 500,00 BTU. For high-
demand applications, 2, 3 or 4 Cyclone units can be installed in a
manifold conguration, delivering total storage up to 520
gallons and total input up to 2 million BTU. Cyclone Xi provides
outstanding hot water output, with dramatic savings on
operating costs compared to units with standard 80% efciency.
A. O. Smith’s leading-edge engineering delivers conventional
power vent or sealed combustion power direct vent versatility,
low NOx emissions, and excellent space-saving characteristics.
Submerged Combustion Chamber, With Helical Heat
Exchanger Coil
Positioned in center of tank, surrounded by water to
virtually eliminate radiant heat loss from chamber
Spiral heat exchanger maximizes efficiency of heat transfer
to the water stored in the tank
Top mounted burner and spiral heat exchanger work
together to minimize harmful effects of calcium/lime
accumulation
PermaGlas
®
Ultra Coat
Glass Lining
Exclusive process provides superior protection against
corrosion in varying water conditions
Powered Anodes are of permanent design and do not
require replacement unless damaged
Both sides of heat exchanger coil are glasslined for
protection against flue gas condensate inside coil
Advanced Electronic Control System with
LCD Display
iCOMM Compatible and can be monitored from remote
locations. Call 1.888.WATER02 for more information
Provides detailed water heater status information
Precise temperature control
Built-in diagnostics
Run history information
Various Venting Options
Conventional and sealed-combustion power venting
(vertical or sidewall) allows for various venting options
(See instruction manual for complete venting installation
instructions and allowable venting lengths)
Direct vent intake and exhaust pipe can terminate
separately outside building or through single opening
using concentric vent assembly
Uses inexpensive PVC, CPVC or ABS pipe for venting
Compliance
Meets the Thermal efficiency and standby loss
requirements of the U.S. Department of Energy and
current edition of ASHRAE/IESNA90.1
Complies with
(models 300,
400 & 500)
(models 120, 150,
199 & 250)
AOSCA80000 R Oct 2011 Com Catalog:108078_ResidentialFul#7A635.qxd 10/28/11 5:50 PM Page 14