Notes: For hard water systems with water hardness greater
than 12 grains per gallon, A. O. Smith recommends a water
softener be installed and maintained.
The factory installed/supplied pump is sized to maintain a
T of
25°F through the water heater at 100% fire. In addition to the
pressure loss through the water heater, the factory supplied
pump is sized for an additional 50 feet of equivalent feet of
piping between the water heater and a storage tank. Consult the
factory for systems where the piping between the water heater
and the tank exceed 50 equivalent feet.
RECOMMENDED FLOW RATES @ 0-12 GRAINS PER GALLON
MODELS
TEMPERATURE
RISE (T °F)
GPM
PRESSURE LOSS
IN FEET OF HEAD (P)
XWH 1000 25 70 17.5
XWH 1300 25 99 22
XWH 1700 25 129 23
XWH 2000 25 153 17.5
XWH 2600 25 198 22
XWH 3400 25 261 23
MODELS
(XWH)
TYPE
OF
GAS
MAXIMUM
SUPPLY PRESSURE
MINIMUM
SUPPLY PRESSURE
INCHES
W. C.
kPa
INCHES
W. C.
kPa
1000, 1300, 1700,
2000, 2500, 3400
Natural 14.0 3.49 4.0 1.0
Propane 14.0 3.49 4.0 1.0
GAS PRESSURE REQUIREMENTS
FLOW RATE
ELECTRICAL REQUIREMENTS
MODEL
SUPPLY
VOLTAGE
(VOLTS)
FREQUENCY
(HZ)
CURRENT
(AMPS)
ELECTRICAL NOTES:
XWH-1000
120V
60
30
A dedicated, single phase,
30/60 amp circuit breaker
with a grounded neutral
should be provided to supply
power to the water heater.
XWH-1300
120V
60
30
XWH-1700 120V 60 30
XWH-2000
120V
60
60
A dedicated, single phase,
60/60 amp circuit breaker
with a grounded neutral
should be provided to supply
power to the water heater.
XWH-2600
120V
60
60
XWH-3400
120V
60 60
AIR INTAKE TERMINATION (PVC) PART #s
Models Pipe Size Combustion Air Intake
(Elbow)
XWH 1000
6" 321764-000
XWH 1300
XWH 1700
8" 321764-001
XWH 2000
XWH 2600
XWH 3400 10" 321764-002
DIRECT VENT VERTICAL
VERSATILE MULTI-VENTING CONFIGURATIONS
APPROVED VENT AND AIR INTAKE FITTINGS
HORIZONTAL VENTING
DIRECT VENT HORIZONTAL
DIRECT VENT, HORIZONTAL VENT VERTICAL INTAKE
DIRECT VENT, HORIZONTAL VENT VERTICAL INTAKE
Direct or sidewall vent for up to 100 equivalent feet of pipe. Lower installation cost with approved CPVC/PVC venting
material – uses CPVC for first 10 feet and PVC thereafter. Also approved for use with UL approved AL 29-4C stainless steel
venting materials. For the detailed venting instructions review the XP water heater instruction manual at
www.hotwater.com.
EXHAUST/VENT TERMINATIONS (PVC) PART #s
Models Pipe Size Vertical
(PVC Rain Cap)
Horizontal
(PVC Tee w/Screens)
XWH 1000 6" 320884-000 321765-000
XWH 1300
8" 320884-001 321765-001
XWH 1700
XWH 2000
XWH 2600
XWH 3400 10" 320884-002 321765-002
Please note: When direct or sidewall venting, the water heater’s CSA certification requires that only the above approved vent and combustion air intake terminations be used.