Brochure
26
Power Burner Water Heaters
Power burner models provide
thermal efficiencies of 80%
These gas power burner models provide an outstanding thermal
efficiency of 80% or more and are suitable for commercial applications.
Small Volume BTP Quality Features:
n
UL listed power burner
n
ASME construction
n
CSA Certified and ASME rated T&P relief valve
n
Handhole cleanout(s) for easy maintenance
n
Three-year limited tank warranty
n
Fully automatic controls ensure safe, efficient operation
n
Barometric draft damper ensures correct airflow in the vent
n
Factory Start-up Included, required for activating warranty and
assuring quality performance
n
Mounted on rugged channel iron skids for easy transport during
installation
n
Multiple anodes for extra protection against tank corrosion
n
Flame inspection port opening for visual inspection of flame
characteristics during operation
n
Spark pilot ignition
n
Factory-installed burner for easy installation
n
BTP(V) 540 and 650 comply with SCAQMD 1146.2 of 14 ng/J or 20 ppm.
The 740 complies with Texas and other areas of 20 ng/J or 30 ppm.
Other units are not low NOx applicable.
n
Meets the Thermal efficiency and standby loss requirements of the
U.S. Department of Energy and current edition of ASHRAE/IESNA90.1
n
Contact Canadian customer service for availability in Canada
n
3-year limited tank warranty
Options (Not Available On All Models)
n
5-year limited tank warranty
n
3 vent options: atmospheric, sidewall and direct vent
Shown here is the power burner combustion chamber used in the BTP-540A,
BTP-650A & BTP-740A models. These models can vent through a side wall up to
100 ft. without an external blower.
1. Exclusive PermaGlas
®
Ultra Coat
™
Glasslined Tank protects tank surfaces and all
welds from the corrosive effects of hot water.
2. Proylite 3100 Chamber Wall retains heat, ensuring cool operation and maximum
heat transfer to water, not the room.
3. Premix Combustion System provides super clean low-NOx flame. Helps eliminate
hot spots and uneven heat transfer.
4. Sealed Combustion Chamber reduces heat loss.
All dimensions in inches
*Available with optional horizontal sidewall or sealed direct vent
termination kits (specified at time of order).
MODEL
NO.
GAL.
CAP.
RECOVERY
CAPACITY/GPH
100°F RISE
VENT
SIZE
INPUT
BTU/HR
NATURAL
GAS
HT. DIA.
APPROX.
SHIP.
WEIGHT
BTP-139 86 136 6 140,000 74 3/4 27 3/4 556
BTP-199 86 193 6 199,000 74 3/4 27 3/4 545
BTP-270 86 262 8 270,000 74 3/4 27 3/4 547
BTP-370 75 359 8 370,000* 74 3/4 27 3/4 634
BTP-139A 86 136 6 140,000 74 3/4 27 3/4 658
BTP-199A 86 193 6 199,000 74 3/4 27 3/4 635
BTP-270A 86 262 8 270,000 74 3/4 27 3/4 632
BTP-370A 75 359 8 370,000* 74 3/4 27 3/4 731
BTP(V)-540A* 85 523 9 540,000 93 29 1/2 950
BTP(V)-650A* 85 630 9 650,000 93 29 1/2 950
BTP(V)-740A* 85 718 9 740,000 93 29 1/2 950
AOSCA80000 R July 2014 Commercial Catalog_108078_ResidentialFul#7A635.qxd 7/16/14 4:28 PM Page 26