Brochure

18
Induced Draft
BTN Gas Models
80% thermal efciency
Low NOx
The Master-Fit
®
Plus BTN series meets Southern California Energy
Commission (CEC) and Texas low NOx requirements of less than
40 ng/J and features an induced-draft design. This provides more
efficient control of heat through the flue collector. Like all Master-Fit
water heaters, the BTN series provides outstanding performance and
maximum installation flexibility for both new construction and
replacement applications. Each unit is designed to be as much as a
foot shorter than the models they usually replace, and multiple
options for placement of water connections and low installation
clearances are additional installer-friendly features.
The Eliminator
Self-Cleaning System
As deposits of lime and other sediments accumulate inside the tank,
they form a barrier between the burner and the water, concentrating
heat around the critical weld areas. The result is reduced energy
efficiency, higher operating costs, and a greater risk of premature
tank leaks.
The Eliminator
directs incoming cold water under pressure
to sweep the bottom of the tank to keep sediment
moving so it doesn’t accumulate. Reduced sediment
build-up helps maintain rated thermal efficiency and
reduce water heating costs. The self-cleaning
system also helps prolong tank life to ensure year
after year of reliable service.
Built-In Induced Draft Blower
n
Factory-mounted on top of unit and pre-wired for easy installation
n
Provides power-induced draft of combustion make-up air prior to
burner ignition
n
Requires no draft hood or barometric damper
Rated As Category 1 Appliance
n
An excellent option for retrofit and upgrade installations
n
Uses standard metal single-wall type B” vent, can be commonly
vented with other Category 1 appliances
n
Vent connects directly to blower outlet
Three Water Connection Options
n
Hot and cold water connections can be made through front, top
or rear of unit
n
The Eliminator
system operates when cold water is connected
through front
PermaGlas
®
Ultra Coat
Glass Lining
n
Exclusive process provides superior protection against corrosion
n
CoreGard
anode rods with stainless steel core provide additional
corrosion protection
Compliance
n
Meets the Thermal efficiency and standby loss requirements of
the U.S. Department of Energy and current edition of
ASHRAE/IESNA90.1
n
Models comply with California Energy Commission (CEC) and
Texas low NOx and other Air Quality Management Districts with
NOx emission requirements of less than 40 ng/J
AOSCA80000 R July 2014 Commercial Catalog_108078_ResidentialFul#7A635.qxd 7/16/14 4:26 PM Page 18