User Guide
69 Page
Troubleshoong
Owner's Guide
Remote
Green
LED
Malfunction
description
Diagnosis
611
Four
Times
Fan motor fault
Check for connection/breakage of wires, dust buildup in the fan
motor (Part #103) and/or burn marks on the computer board
(Part #701).
Check for frozen/corrosion of connectors (Part #103).
631
Four
Times
Pump fault
Check for connection/breakage of wires in the pump(Part #726).
Check if the water in the pump has frozen (Part #726).
651
Four
Times
Flow adjustment
valve fault (Easy-
Link System only)
Inspect the flow adjustment valve (Part #402), for connection/
breakage of wires, locked motor drive due to scale buildup, and/
or water leakage.
661
Four
Times
Bypass valve fault
Inspect the bypass valve (Part #403), for connection/breakage
of wires, locked motor drive due to scale buildup, and/or water
leakage.
701
One
Time
Computer board fault
Check for connection/breakage of wires (Part #714).
711
One
Time
Gas solenoid valve
drive circuit failure
Refer to the 111 and 121 error codes.
721
Six
Times
False flame
detection
Check if there is leaking from heat exchanger (Part #401).
741
N/A Miscommunication
between water
heater and remote
controller
Check the model type of the remote controller.
Inspect the connections between the water heater and remote
controller.
Check the power supply of the water heater.
751
N/A Miscommunication
between water
heater and built-in
controller (Indoor
model only)
Inspect the connections between the water heater and built-in
controller.
Check the power supply of the water heater.
761
N/A Miscommunication
in Easy-Link System
Check if the connections between the parent unit and the child
units are correct. Refer to pp. 40 and 41.
941
Five
Times
Abnormal exhaust
temperature
(Indoor model only)
Check if the inlet and return water temperature is higher than
140°F (60°C) in the recirculation system.
991
Five
Times
Imperfect
combustion
Check the gas type of the water heater.
Inspect the environment around the water heater. Determine
how long the unit has been installed.
Check the altitude/elevation of the area of where the water
heater is installed.
Check if there is any blockage in the intake air and/or exhaust.
If the water heater is installed as a direct-vent system, check
whether there is enough distance between the intake air terminal
and the exhaust terminal.
Check if there is grease and/or dirt in the burner (Part #101) and
the fan motor (Part #103), especially if the water heater has been
installed in a contaminated area.