-Fault Analysis of Error Codes-
If the error code is displayed on the computer board of the water heater or remote controller, please
check the following. After checking, consult with the manufacturer.
Troubleshoong
Owner's Guide
Remote
Green
LED
Malfunction
description
Diagnosis
031
One Flash
Incorrect DIP switch
setting
Check the DIP switch settings on the PCB (Part #701).
101
Five Flashes
Warning for the “991”
error code
Check the gas type of the water heater.
Check if there is any blockage in the intake air and/or
exhaust.
Check to make sure that there is enough distance between
the concentric vent terminal and other exhaust vent
terminals.
Check the altitude/elevation of area of where the water
heater is installed.
Check if there is grease and/or dirt in the burner (Part #101)
and the fan motor (Part #103), especially if the water heater
has been installed in a contaminated area.
111*
Three Flashes
Ignition failure Check if the Hi-limit switch (Part #412) is properly
functioning.
Check for connection/breakage of wires (Part #413, 708,
709), burn marks on the computer board (Part #701), and/or
soot on the flame rod (Part #108).
Check if there is a buzzing spark ignition sound coming
from the burner (Part #101) when the water heater
prepares for combustion.
Listen for the double “clunk” sound coming from the gas
valve assembly (Part #102) when the water heater goes
into combustion.
Check if there is leaking from heat exchanger (Part #401).
121*
Three Flashes
Loss of flame Check if the Hi-limit switch (Part #412) is functioning
properly.
Check for connection/breakage of wires (Part #413, 708,
709), burn marks on the computer board (Part #701),
and/or soot on the flame rod (Part #108).
Check if there is leaking from heat exchanger (Part #401).
311*
Two Flashes
110C & 310C:
Outlet thermistor
failure
510C:
Heat exchanger
thermistor failure
Check for connection/breakage of wires and/or debris on
thermistor (Part #407, 408, 411, 713).
321*
Two Flashes
Inlet thermistor failure
331*
Two Flashes
Outlet thermistor
failure
(510C model only)
391
Two Flashes
Air-fuel ratio rod failure Check for connection/breakage of wires (Part #709) and/
or soot on the AFR rod (Part #108).
441
Two Flashes
Flow sensor failure
(Only Easy-Link &
Multi-Unit System)
Check for connection/breakage of wires and/or debris on
the flow sensor impeller (Part #402).
510
Six Flashes
Abnormal main gas
solenoid valve
Check for connection/breakage of wires (Part #708) and/
or burn marks on the computer board (Part #701).
551
Six Flashes
Abnormal gas
solenoid valve
Check for connection/breakage of wires (Part #708) and/
or burn marks on the computer board (Part #701).
611*
Four Flashes
Fan motor fault Check for connection/breakage of wires, dust buildup
in the fan motor (Part #103) and/or burn marks on the
computer board (Part #701).
Check for frozen/corrosion of connectors (Part #103).