User Guide

On-Demand Rack System • 7
INSTALLATION
isolated from the gas supply
piping system by closing its
manual shuto valve during any
pressure tes ng of that system
at test pressures equal to or less
than 1/2 psi (3.5 kPa).
7
Connect the
Power Supply
• Con rm that the installa on
complies with local electrical code
requirements. In the absence of
such requirements, follow the
Na onal Electrical Code ANSI/NFPA
70 (current edi on) in the U.S. or
CSA C22.1 Canadian Electrical Code,
Part 1 (current edi on) in Canada.
Indoor models include a factory
installed, 6-foot (1.83m) long power
cord.
Outdoor models must be hard wired.
The water heaters require 120 VAC,
60 Hz electrical power supply that is
properly grounded.
• The electrical connec on must
provide a means of disconnec on (to
terminate power to the water heaters
for servicing and safety purposes).
Also, the water heaters must be
electrically grounded. Do not a ach
the ground wire to either the gas
or water piping. Installa on must
comply with all code requirements.
Power Requirements
One 15 amp breaker can adequately
protect up to seven water heaters.
Example:
Number of
Heaters
Breaker Size
(Amps)
Number of
Breakers
1 to 7 15A 1
8 to 14 15A 2
15 to 20 15A 3
Refer to the water heaters’
Installation Manual and Owner’s
Guide for instructions.
8
Configure the
System
If your rack system contains up to
four water heaters, configure it with
the Easy-Link System.
Refer to the
water heaters’ Installation Manual and
Owners Guide for instructions.
However, if your rack system contains
five or more water heaters, you must
install and configure a multi-unit
controller (part number 100112691).
A multi-unit controller can connect
up to 20 water heaters, making it
easy to use multiple racks.
• The mul -unit controller is available
as an accessory item. It can be
ordered along with the rack system
or later through your local service
agency/installer.
If a mul -unit controller is ordered
with a wall mount or free standing
(in-line) system, it can be installed
on either end of the assembly.
However, a controller-moun ng
kit is necessary to complete
the installa on. This kit is sold
separately and must be installed
on site by the installing contractor.
(Kit part number: 100211495.) The
moun ng kit includes two 14-in. long
moun ng bars and two moun ng
brackets.
Wall mounted rack systems only:
Install the bars onto either end
as shown in Figure 4.
Free standing rack systems: The
mul -unit controller may be
mounted on either side of the
rack or on a nearby wall. The
moun ng hardware must be
eld supplied.
See also Piping Requirements, p. 5.
9
Final Installation
Checklist
WARNING
Do not install outdoor systems indoors.
Nut
T-Bo l t
A.) Place T-Bolt through bracket
ŚŽůĞĂƐƐŚŽǁŶĂƚůĞŌƚŚĞŶ
start nut on opposite side.
Repeat for other bracket.
Bracket Hole
B.) Insert head of T-Bolt into
dͲŚĂŶŶĞůƐůŽƚƚŚĞŶ
rotate it 90°. Tighten nut.
(Torque: 25 Nm +/- 5%)
T-Channel Slot
T-Bo l t
Nut
DŽƵŶƟŶŐ
Bar
DŽƵŶƟŶŐ
Bar
/ŶƐĞƌƚƚŚĞŶ
Rotate 90°
to lock.
ͿĞƚĞƌŵŝŶĞůŽĐĂƟŽŶ
ŽĨƐĞĐŽŶĚŵŽƵŶƟŶŐ
bar. It must align
ǁŝƚŚƚŚĞŵŽƵŶƟŶŐ
hole(s) on the
ŵƵůƟͲƵŶŝƚ
ĐŽŶƚƌŽůůĞƌƐŇĂŶŐĞ
D.) Repeat steps A and B
to install the second
ŵŽƵŶƟŶŐďĂƌ
A
B
C
Figure 4: Controller Bracket
Installation for Wall
Mounted Systems.