Install Instructions
Installation
1. Consultandfollowallapplicablestateandlocalplumbingcodes.
2. TurnoallequipmenttobefedbythePP-AS20.
3. LocateWatersupplyshutovalveandturno.
4. Locatesuitablelocationforinstallation.
5. Mountunittowallwithincludedmountingbracket.(Ensurewallmaterialisstable
enoughformountingpurposes.)
6. Runasuitablelinefromtheincomingcoldwaterlinetotheinlet(left)sideoftheleft
sideoftheProductPreserverssystem.
NOTE: Do not over tighten connection ttings. Do not use pipe dope. Do not use more than
seven layers of plumber’s tape.
7. Abypasslineisrecommendedtobeinstalled.(Notincluded)
8. SelectasuitablesizetubingtorunfromtheProductPreserversoutlettothetankless
waterheater.Adrainvalve(notincluded)isrecommendedtobeinstalledafterthe
lterforushingandltercartridgechanges.
NOTE: If not installing a drain valve, do not connect the tubing to the tankless water heater at
this time. This line will be used to ush the system.
9. Oncesystemisinstalledslowlyapplypressurebyslightlyopeningfeedwatervalve.
Ifdrainvalveisinstalled,openvalvetopurgeanyairthatisintheline.
10. Aftersystemhasfullypressurizedinspectforanyleaks.
11.Flushsystembyopeningdrainlinevalve.Ifnovalvewasinstalled,ushBEFORE
connectinglinetothetanklesswaterheater.Flushfor2minutes.
12. Ifthereisnotapressurereliefvalveinstalledonthetanklesswaterheaterhotwater
outlet,installabrassteeonthetanklessoutlet.Installapressurereliefvalvetoone
sideofthetee.Connectthehotwaterlinetotheothersideofthetee.
13. Noteinstallationdateforreplacementelementscheduling.Changetheltercartridge
atleastonceeverytwoyears.
Y
Installation
Recirculation System
Installation
BasicwithBypassLoopandOptionalPP-PRE-AS20Pre-Filter
Important:
Do not over tighten ttings as this may cause leakage and broken ttings.
Do NOT use pipe dope. The use of pipe dope voids the warranty. You may
use plumber’s tape. Leave two-three threads exposed and do not exceed
seven layers of plumber’s tape. More than seven layers will cause the nipple
to crack and leak.