User's Manual

MHPTV TX User Manual
MHPTV-USR-DOC-V3.0, 10/18/2019 Page 60 of 148
2.1 Control Unit
2.1.1 Control UnitCTL-S
For 1, 2 and 3 PA configurations, the TX Control Unit CTL-S consists of a pre-
amp and a powerful control system. It receives the RF input(s) from the exciter(s),
performs the pre-amplification, and sends RF output to a PA or an external N-way
splitter to feed up to 3 PAs. The CTL-S communicates over an RS-485 serial bus to
the PAs and Exciter(s) installed in the system and monitors system Forward,
Reflected, and Reject load power.
Front panel
The front panel of the Control Unit is shown below.
Color touch screen
LED_OK
If the green light is ON, then the transmitter is working in OK mode.
LED_ALARM
If there is an alarm, the red light is ON, and the transmitter will shut down its
output. The most common alarms include Over-drive/over-current of PA
modules or Preamp, high reflected power of PA modules or Preamp, high
absorbed power, over temperature of PA modules or Preamp, etc. Please refer
to Status Bar and LOG from the touch screen of Control Unit for details.
RESET (reserved)