User's Manual

MHPTV TX User Manual
MHPTV-USR-DOC-V3.0, 10/18/2019 Page 99 of 148
interface.
Important: Never run Optitune at full power, otherwise it may cause damage to
the transmitter and void the warranty. It is required only running Optitune with
the guidance from the manufacturer.
Local Control:
1. Make sure AGC is turned OFF, then lower the overall transmitter forward
power level to 1kw.
2. Navigate to the System screen on the Controller by pressing the CONFIG
button and then selecting AmpCF (Amplifier Configuration)
The AmpCF screen is used to configure advanced settings of the TX System and
PAs and is locked with a password. When pressing the “AmpCf” button in the Config
Menu, a pop-up window requiring a password will appear. Please enter the “AmpCf”
password “27654” and then press “OK”.