LED_ALARM
The red light will be on if there is any alarm
The red light will be off if there is no alarm
RESET: To reset the IP to default (192.168.1.200).
Rear Panel
The rear panel of PA is shown below with ports described as follows.
RF_OUT
Connector: 7/16 DIN
Impedance: 50 Ω
Note: To send out RF signal to the input of Power Combiner (attached to the
cabinet). It must always be connected to a load.
RFMON
Connector: SMA
Impedance: 50 Ω
Note: Loop out of RF_OUT for monitoring.
RF_IN
Connector: N
Impedance: 50 Ω
Note: To receive RF signal from RFOUT1/RFOUT2 of Control Unit.
REMOTE
Connector: DB9-M
Note: To be connected to PRS485-1/ PRS485-2 of Control Unit for internal
communication between PA and Control Unit.
AC220V input: To be connected with Power Supply System.