Instructions

S Registers
79 (84)
Miscellaneous Registers (continued)
Register
Name
Value Range
Default Value
Description
1015
Radio Mode
0..3 3
Configures which radios should be enabled
0: All radio off
1: Enable only Bluetooth
2: Enable only WLAN
3: Enable Bluetooth and WLAN
1016
Log level
0..3 1
Configures what kind of events that should be
presenred in the event log
0: Off, No events should be logged.
1: Error, Error events should be logged.
2: Warning, Warning and Error events should be
logged.
3: Verbose, All events should be logged.
Bluetooth Registers
Register
Name
Value Range
Default Value
Description
2000
Reserved
2001
Reserved
2002
Reserved
2003
Reserved
2004
Reserved
2005
Reserved
2006
Inquiry Class of
Device Filter
0..4294967296 0x00020300
A found device must match this bitmask to be
reported to the higher layers, e.g. to find all
networking devices, bit 17 should be set
(0x00020300 or 131840). Bit 0-1 and 24-31 are
reserved and will be ignored
2007
Reserved
2008
Reserved
2009
Reserved
2010
Max Number of
Connections
0..7 1
The default value is set at production time and
might differ for different product models. It is
readable using the AT*AMSBC? command.
2011
Reserved
2012
External
Connection
Control
0..1 0
0: Disable.
1: Enable.
2013
Reserved
2014
Reserved
2015
Reserved
2016 Connect to
Name Scheme
0..2 1
0: Connect to first name (first found). This will
make a limited inquiry searching for 1 unit,
get the name of the found unit and, if the name
matches, connect to it.
1: Connect to best name (highest RSSI value). This
will make an inquiry, sort the devices regarding to
the RSSI value.
Then it will start from the device with best RSSI
value, get the name and connect if it matches the
desired name.
If it fails, it will go to the next device and so on.
(default)
2: Connect to name. This will make an inquiry and
then get the name of the found devices.
When a matching name is found, a connection
attempt will be done. If the connection fails, it will
try with the next found and so on.
Wireless Bolt
/ Wireless Bridge II
Reference Guide
SCM-1202-004 1.7 en-US