To Congure IP Sengs Manually
Figure 15. Modbus TCP IP Sengs, DCHP disabled
1. Deselect the DHCP enabled checkbox.
2. Congure the IP sengs.
Seng Descripon
IP address The Modbus TCP network IP address in IPv4 dot-decimal notaon
Subnet mask The Modbus TCP network Subnet mask in IPv4 dot-decimal notaon.
Gateway address The Modbus TCP network Gateway address in IPv4 dot-decimal notaon.
If there is no gateway available, set the Gateway address to: 0.0.0.0
Primary DNS server The Modbus TCP network Primary DNS in IPv4 dot-decimal notaon.
Secondary DNS server The Modbus TCP network Secondary DNS in IPv4 dot-decimal notaon.
DHCP Enabled
If you change a value and click Refresh, the value is reset to the last applied value.