Manual

Description
8 (16)
2.3.2 Live List (Master Configurations Only)
The Live List provides the active status of the slaves associated with an on-board network
interface acting as master. The list is assembled by the master interface and forwarded to the
other network each gateway cycle.
The Live List functionality is disabled by default and must be enabled for the master interface
through Anybus Configuration Manager.
Offset bit 0 bit 1 bit 2 bit 3 bit 4 bit 5 bit 6 bit 7
0
Slave 0 Slave 1 Slave 2 Slave 3 Slave 4 Slave 5 Slave 6 Slave 7
1
Slave 8 Slave 9 Slave 10 Slave 11 Slave 12 Slave 13 Slave 14 Slave 15
2
Slave 16 Slave 17 Slave 18 Slave 19 Slave 20 Slave 21 Slave 22 Slave 23
3
Slave 24 Slave 25 Slave 26 Slave 27 Slave 28 Slave 29 Slave 30 Slave 31
4
Slave 32 Slave 33 Slave 34 Slave 35 Slave 36 Slave 37 Slave 38 Slave 39
5
Slave 40 Slave 41 Slave 42 Slave 43 Slave 44 Slave 45 Slave 46 Slave 47
6
Slave 48 Slave 49 Slave 50 Slave 51 Slave 52 Slave 53 Slave 54 Slave 55
7
Slave 56 Slave 57 Slave 58 Slave 59 Slave 60 Slave 61 Slave 62 Slave 63
Bit set (1) = Slave active
Bit cleared (0) = Slave not active
The exact definition of each set or cleared bit depends on the network interface used. See the
documentation for the respective interface for more information.
2.3.3 Network-specific Status
Some network interfaces may provide additional registers or status lists. See the documentation
for the respective interface for more information.
Anybus
®
X-gateway
User Manual
HMSI-27-262 4.0 en-US