Instructions
66
Doc: HMSI-27-314, Rev. 3.10Anybus Communicator EtherNet/IP / Modbus-TCP User Manual
11.3 Sub-network Parameters
Communication
These parameters specify the actual communication settings used for the sub-network.
Start- and End Character
Note: These parameters are only available in Generic Data Mode.
Start and end characters are used to indicate the beginning and end of a serial message. For example, a
message may be initiated with <ESC> and terminated with <LF>. In this case, the Start character would
be 0x1B (ASCII code for <ESC>) and the End character 0x0A (ASCII code for <LF>)
Timing (Message Delimiter)
The parameters in this category differs slightly between the different protocol modes.
•Master Mode
The Message Delimiter specifies the time that separates two messages in steps of 10 ms. If set to
0 (zero), the gateway will use the standard Modbus delimiter of 3.5 characters (the actual number
of ms will be calculated automatically based on the currently used communication settings).
• Generic Data Mode
The Message Delimiter specifies the time that separates two messages in steps of 10 µs.
Parameter Description Master Mode and Generic Mode
Bitrate (bits/s) Selects the bit rate 1200
2400
4800
9600
19200
35700
38400
57600
Data bits Selects the number of data bits 7, 8
Parity Selects the parity mode None, Odd, Even
Physical standard Selects the physical interface type RS232, RS422, RS485
Stop bits Number of stop bits. 1, 2
Parameter Description Valid settings
End character value End character for the message, ASCII 0x00–0xFF
Use End character Determines if the End character shall be used or not Enable / Disable
Start character value Start character for the message, ASCII 0x00–0xFF
Use Start character Determines if the Start character shall be used or not Enable / Disable