2.3.4 Generic Data Mode
In this mode, there is no master-slave relationship between the nodes on the sub-network and the gate-
way. Any node (including the gateway) may spontaneously produce or consume a message. Nodes are 
not obliged to respond to messages, nor do they need to wait for a query in order to send a message.
In the figure above, the Anybus Communicator ‘consumes’ data ‘produced’ by a node on the sub-net-
work. This ‘consumed’ data can then be accessed from the higher level network. This also works the 
other way around; the data received from the higher level network is used to ‘produce’ a message on the 
sub-network, for ‘consumtion’ by a node.
2.3.5 DF1 Master Mode
Please refer to “DF1 Protocol Mode” on page 86.
Subnetwork Devices
Control System
 Gateway