Instructions

CIP Object Implementation 110
Doc: HMSI-27-314, Rev. 3.10Anybus Communicator EtherNet/IP / Modbus-TCP User Manual
22.4 Assembly Object, Class 04h
22.4.1 General Information
Object Description
This object provides access to the I/O Data in the input and output data areas in the Anybus Commu-
nicator.
See also...
“EtherNet/IP” on page 23
“Fieldbus Settings” on page 64
Supported Services
Class services: Get Attribute Single
Instance services: Get Attribute Single
Set Attribute Single
22.4.2 Class Attributes
22.4.3 Instance 64h (100) Attributes
This instance corresponds to I/O data (input) in the gateway.
Note: If the I/O input data size is set to 0 this instance will NOT be initialized.
22.4.4 Instance 96h (150) Attributes
Note: If the I/O output data size is set to 0 this instance will NOT be initialized.
# Access Name Type Value Description
1 Get Revision UINT 0002h Revision 2
2 Get Max Instance UINT - The highest initiated instance no.
# Access Name Type Value Description
3 Get Data Array of BYTE - Data produced by the gateway
# Access Name Type Value Description
3 Set Data Array of BYTE -
Data consumed by the gateway
a
a. Rockwell Automation PLCs have the first four bytes consumed by a device defined as status information. This
behavior is specific to devices from Rockwell Automation and is not defined in the EtherNet/IP specification.
However, since all known PLCs are implemented this way, the Anybus Communicator adopts this behavior
and strips off the corresponding four bytes from the consumed data.