User's Manual
Table Of Contents
- Chapter 1:INTRODUCTION
- Chapter 2:INDICATIONS, CONTRAINDICATIONS AND WARNINGS
- Chapter 3:WIRING AND CONTROL PANEL OF CONSOLE
- Chapter 4:OPERATION INSTRUCTION FOR ESNAVI SOFTWARE
- 4.1Installing Software
- 4.2Uninstalling Software
- 4.3Basic Operation of Software
- Chapter 5:USAGE OF CAPSULE
- Chapter 6:USAGE OF DATA RECORDER
- Chapter 7:INSTALLATION AND TRAINING
- Chapter 8:MAINTENANCE
- Chapter 9:WARNINGS, CAUTIONS AND TROUBLESHOOTING
- 9.1ESNavi Error Messages
- 9.1.1.1.1.Check if camera is connected firmly
- 9.1.1.1.2.Equipment initialization error
- 9.1.1.1.3.Port "COM7" does not exist
- 9.1.1.1.4.Video monitoring connection fails
- 9.1.1.1.5.Port "COM8" does not exist
- 9.1.1.1.6.Serial port initialization error
- 9.1.1.1.7.Port "COM4" does not exist
- 9.1.1.1.8.Cannot connect to Data Recorder
- 9.1.1.1.9.Password error
- 9.1.1.1.10."Print error" prompt box
- 9.2Problems with Translational Rotation Platform
- 9.3Problems with Capsule
- 9.4Problems with Data Recorder
- 9.5Problems with Locator
- 9.1ESNavi Error Messages
- Chapter 10:TECHNICAL SPECIFICATIONS
- Chapter 11:SYSTEM LABELING
NaviCam
®
Stomach Capsule User Manual Page | 104
AnX Robotica Corp. UM-NCES-ST-01 Rev 1
6.1.2 Operation Instruction
Related marks and position of power switch, USB interface, LED, keys on the Data
Recorder are shown in Figure 6- 3.
Figure 6- 3 Data Recorder Operation Manual
①: Alarm indicator, yellow;
⑦: Power switch;
②: Run indicator, green;
⑧: USB interface to connect computer;
③④⑤: Battery capacity indicators;
⑨: Charging port.
⑥: Charge indicator, white;
Hold down the power switch without releasing until all the five LEDs (marked as ①
②③④⑤ in Figure 6- 3) are lit up to power on the Data Recorder normally. Click the
related button in the ESNavi to power the Data Recorder off. If the Data Recorder is
not connected to the computer via USB, and therefore no capsule information is
detected for a consecutive 15 minutes, it will automatically power off to save energy.
If the yellow LED alarm indicator (marked as ① in Figure 6- 3 with word “alarm”
under it) is always on, it indicates that no capsule is detected. If on/off continues
flashing, it indicates that the capsule is present, however the upper-level software has
not yet issued a command to let the capsule capture images. The green LED run
indicator (marked as ② in Figure 6- 3 with word “run” under it) will be lit up once it
receives the image information from the capsule and off again quickly; it will light up
again once it receives the next image information and then off again. The received
image information captured by the capsule will also be marked accordingly.
The green LED battery capacity indicators (marked as ③④⑤ in Figure 6- 3, with
battery capacity icon under it, three lattices, two lattices and one lattice specifically)