Specifications
UFL-420/440 WATER FILTRATION SYSTEM
8
P/N 1011055 Rev. F 12/13
PERFORMANCE DATA SHEET
Filter Cartridge Capacities
Maximum Operating Pressure 100 psig (690 kPa)
Maximum Operating Temperature 100°F (38°C)
Minimum Operating Temperature 40°F (4°C)
Maximum Trans Membrane Pressure 45 PSI (3.1 Bar)
pH Range 3-10
MWCO 100 kD
NSF/WQA Certified Rated
Service flow:
UFL-420 7.9 gpm (30 l/m)
UFL-440 13 gpm (49 l/m)
This system has been tested according to NSF/ANSI
Standard 42 and 53 for reduction of the substances
listed below. The concentration of the indicated sub-
stances in water entering the system was reduced to a
concentration less than or equal to the permissible limit
for water leaving the system, as specified in NSF/ANSI
42 or 53. While testing was performed under standard
laboratory conditions, actual performance may vary.
Performance Claims for Percent Reduction
Substance Influent
Challenge
Concentration
Reduction
Requirement
Minimum
%
Reduction
cyst
1
minimum
50,000/L
99.95% 99.95%
Turbidity 11 ± 1 NTU ≤ 0.5 NTU 99.1%
Particulate Class I
Particles 0.5 to <
1µm
at least 10,000
particles /mL
≥ 85% N/A
1
based on the use of microspheres or Cryptosporium parvum oocysts
NOTE: The NSF/WQA information provided applies
to the Ultra Filter cartridge.
Do not use with water that is microbiologically
unsafe or of unknown quality without adequate dis-
infection before or after the system. Systems certi-
fied for cyst reduction may be used on disinfected
waters that may contain filterable cysts.
System Tested and Certified by NSF
International and WQA against NSF/ANSI
Standard 42 and 53 for the reduction of:
Standard No. 42: Aesthetic Effects
Nominal Particulate Reduction Class I
Standard No. 53: Health Effects
Cyst Reduction & Turbidity Reduction
as verified and substantiated by test data.
System Tested and Certified by WQA
against NSF/ANSI Standard 372
for lead-free compliance