Specifications
UFL-420/440 WATER FILTRATION SYSTEM
6
P/N 1011055 Rev. F 12/13
SPECIFICATIONS
CAUTION
All electrical connections must be in accordance
with local electrical codes and any other
applicable codes.
A ground fault circuit interrupter (GFCI) must be
installed on the circuit to this system.
When installed on metallic plumbing, a properly
sized electrical bonding jumper must be installed
across the inlet and outlet pipes serving this
device
A
C
B
A
C
B
Electrical Ratings
Model &
Mfg. No.
Voltage Watts Amps Hertz
UFL-420
9700465
100–240 10 0.4 50/60
UFL-440
9700475
100–240 10 0.4 50/60
Dimensions
Model &
Mfg. No.
Width
(A)
Depth
(B)
Height
(C)
Operating
Weight
UFL-420
9700465
11.5”
(29 cm)
6”
(15 cm)
28”
(71 cm)
28 lbs.
(12.7 kg)
UFL-440
9700475
11.5”
(29 cm)
6”
(15 cm)
47”
(119 cm)
42 lbs.
(19 kg)
UFL-420 UFL-440
Replacement Cartridges
Replacement Cartridge Part No.
UFL-420 L-420 Ultra Filter 7000411
UFl-440 L-440 Ultra Filter 7000412
Electrical Cord & Plug Configurations
Kit Model
Number
Description Configuration
0012146
DC Power Supply
100 - 240 VAC
Includes the
4 plug adaptors
below
NOTE: PLUG STYLE
MAY VA RY
US
NEMA 1-15 (2 pin)
or NEMA 5-15
(3 Pin)
US
NEMA 1-15 (2 PIN)
or NEMA 5-15
(3 PIN)
Euro
CEE 7/16
EURO
CEE 7/16
AS/NZS
3112
AUS
(2 Pin)
AS/NZS 3112
(2 PIN)
AUS
UK
BS 1363
BS 1363
UKUK