Specifications

TACO BELL STEAMER TBS-2X & TBS-1X
12
P/N 1010698 Rev. E 03/04
13
TACO BELL STEAMER TBS-2X & TBS-1X
P/N 1010698 Rev. E 03/04
5. Turn the Rocker Switch (power On/Off) to ON.
6. Press the Cycle Start button and operate the unit
through two complete cycles to purge all air from
the tubes.
NOTE: Water may come out of the calibration
tubes with force. Hold the tubes and cup firmly.
7. Empty all water from the cup, then reinsert the
tubes back into the cup. Press the Cycle Start
button to run one cycle.
The cup should contain 0.8 oz. (25 ml or 25 cc).
If cup contains more or less of this amount, pro-
ceed to Step 8.
8. With the unit positioned at the edge of its location
surface (edge of the counter, table, etc.) slide the
steamer forward approximately 3” to expose the
Water Volume Control on the bottom of the unit
(Figure 7).
9. Using a precision flat blade screwdriver, care-
fully and slowly adjust the control clockwise to
increase or counterclockwise to decrease the
amount of water used per cycle.
10. Repeat steps 7 - 9 until the proper amount of
water level in the cup is achieved.
NOTE: If steamer does not steam properly after
calibration, refer to the Troubleshooting section of
this manual.
NOTE: If calibration kit is missing, use the
Calibration Chart (Figure 8) to figure approxi-
mate volume. Turn the water volume control to
0. Determine your water pressure and locate it on
the chart (left side), then look to the right to find
the volume closest to 0.8 oz. (25 ml or 25 cc). Turn
adjustment clockwise to setting shown at the left of
chart.
Figure 5. Installing Calibration Tubes
Figure 6. Water Measurement
Figure 7. Water Volume Adjustment
Slanted end of tube
MAINTENANCE (continued)
Figure 8. Calibration Chart
Water Volume Adjustment
0 1/4 1/2 3/4 MAX
15 psi 10 ml 20 ml 25 ml 32 ml
20 psi 15 ml 23 ml 30 ml 37 ml
30 psi 16 ml 27 ml 35 ml 48 ml
35 psi 5 ml 20 ml 30 ml 40 ml 50 ml
35 psi 7 ml 21 ml 32 ml 42 ml 55 ml
40 psi 9 ml 22 ml 37 ml 45 ml 60 ml
Water Pressure




CAUTION
Excessive force will damage this control. Do not
turn past built-in stops on the control or damage to
the unit will occur and void the warranty.