Operating instructions
DELUXE FOOD WARMER
14
P/N 1010678 Rev. G 08/08
OPERATION (continued)
Hi-Limit Reset Button
A hi-limit thermostat will turn off electrical power to the
heater if the unit overheats. To reset this thermostat,
allow sufficient time (about 45 minutes) for the unit to
cool down, remove the Cap located on the rear of the
unit (Figure 8) and then fully press the Reset Button .
If the unit requires continuous resetting, contact your
Roundup authorized service agency.
Figure 8. Hi-Limit Reset Button
Reset Button
Cap
Diagnostic LEDs (Timer Models) Only
This control board has 4 diagnostic LEDs described
below.
Green (Program): When lit, indicates the unit is in
Program mode.
Yellow (Audio): When lit, indicates 10-15 VDC is
being supplied to the audio signal. The audio signal
will sound and the LED will be lit for approximately 3
seconds.
Red (Heat): When lit, indicates the unit is calling for
heat by supplying 10-15 VDC to the solid state relay.
When off, indicates the generator surface is up to
temperature.
Green (H2O): When lit, indicates that 24 VAC is being
supplied to operate the solenoid valve used in DFW/
DFWT/DFWF-250 units or to the water pump used in
the DFW/DFWT-150 units.
NOTE: This LED is only lit for approximately
1 second.
Diagnostic LEDs (Non-Timer Models) Only
This control board has 2 diagnostic LEDs described
below.
Yellow (CR2): If lit, indicates the thermistor probe is
disconnected or open. The thermistor should be 100k
ohms +/- 2% at room temperature.
NOTE: The unit will not call for heat. This LED
should NOT be lit during normal operation.
Red (CR4): When lit, indicates that the unit is calling
for heat by supplying 15-20 VDC to the solid state relay.
When off, indicates that the Generator surface is up to
temperature.