TROUBLESHOOTING (continued)
Problem Possible Cause(s) Corrective Action
The unit is not
steaming the product
properly and/or the
product requires
re-steaming.
The Water Pressure Regulator is improp-
erly set.
Adjust regulator to 7-9 PSI. Refer to the sec-
tion titled “Adjusting the Water Pressure
Regulator” in this manual.
The water regulator strainer screen is
clogged.
Clean the strainer according to the
Maintenance section of this manual.
Rotary switches are not correctly set. Set switches to the proper settings shown in
the “Equipment Setup” section of this manual.
The generator water inlet tube is clogged. Clean the inlet tube according to the
Maintenance section of this manual.
The generator needs cleaning. Clean the generator according to the
Maintenance section of this manual.
The unit is not being cleaned as required.
& Monthly cleaning procedures found in the
Maintenance section of this manual.
The generator surface is not hot enough. Preheat the unit and verify that the generator
surface temperature is at least 375° F.
The generator surface
continuously fills with
water ONLY when the
power switch is OFF.
The solenoid valve is leaking due to
debris trapped within its plunger and seat.
Attempt to flush the debris out by increasing
the water regulator to 30 PSI & cycling the
unit several times. Reset the regulator back to
7-9 PSI. If the problem persists. Contact the
Authorized Service Agency for service
The Solenoid Valve is not installed
correctly.
If the Solenoid Valve was replaced, verify that
the “IN” and “OUT” labels on the valve corre-
spond to the water flow.
The generator surface
continuously fills with
water ONLY when the
power switch is turned
ON.
Faulty temperature Control Board Contact your maintenance person or an
Authorized Service Agency for service.
No heat and the rear
front display is on.
Faulty Temperature Control Board. Contact your maintenance person or
Authorized Service Agency for service.