Specifications
STS-200 STEAMER/SCALE
13
P/N 1010929 Rev. B 03/12
A.J. Antunes & Co.
TROUBLESHOOTING
Error Codes
The table below lists the possible error codes displayed by the unit when an error occurs.
NOTE: If any of these errors appear on the Steamer/Scale display, contact the factory.
Error Code Description and Corrective Action
“E1” Program
Rom Error
The program memory in the Steamer/Scale has become corrupted. Have the Steamer/Scale ser-
viced by a qualified Scale Repair Technician.
“E2” Gross
Overload
The Steamer/Scale is in gross overload. The load exceeds the scale’s input range and might
result in damage to the Load Cell. Remove excess weight immediately or Load Cell connections
may be wired in wrong. Ignore this message for the first 5 seconds after powering the Steamer/
Scale.
“E3” Scale
Overload
The Steamer/Scale is in overload. The load on the scale exceeds capacity by more than 103%.
Remove excess weight from the Steamer/Scale.
“E4” Calibration
Span Error
“E5” EEPROM
Error
The setup parameters loaded in nonvolatile memory have been corrupted. The Have the
Steamer/Scale re calibrated by a qualified Steamer/Scale Technician.
“E6” Calibration
Range Error
Steamer/Scale Repair Technician.
Message
Code
Description
888
93
r0.3
Software revision.
Ld0
Loading zero, shown on start up.
don
Indicates that calibration is complete.
SAv
Indicates that the current values are saved into memory.
Unt
Int
Initialize or reset all scale settings in memory.
r b
Release button. Prompts user to release the Zero (On) or hidden buttons.
Message Codes
The table below lists the possible message codes displayed by the unit during operation. Contact the factory if you
have any questions about these message codes.