TESTING THERMOSTAT
See Thermostat under “Component Description & Function” before proceeding.
To test thermostat for continuity:
Disconnect thermostat wires to isolate.
Verify continuity across terminals.
Replace if fails test.
To determine if an “over heating” condition is
caused by a faulty thermostat: Fill the pan with hot
water about 1” (2.5 cm) above the thermostat bulb.
Turn unit on & monitor the water temperature for at
least 30 minutes. Does the water temperature exceed
180 F (82 C)?
If yes, replace thermostat.
To determine if an “under heating” condition is
caused by a faulty thermostat: Fill the pan with hot
water about 1” (2.5 cm) above the thermostat bulb.
Turn unit on & monitor the water temperature for at
least 30 minutes. Does the water temperature reach
at least 150 F (65 C)?
If no, replace thermostat.
Replacement Procedures
Remove side service panel.
Remove thermostat mounting screws & acorn nuts.
Disconnect thermostat wires.
Reinstall wires onto new thermostat.
Install & secure new thermostat with screws & acorn nuts.
NOTE: Cautiously handle the bulb & capillary tubing. Failure to do so
will result in premature thermostat failure.
Test unit for proper operation.