Specifications
CCC-20 TECHNICAL MANUAL
LAST UPDATE 5-1-05
1060005 5/05
TESTING HEATING ELEMENT
See Heating Element under “Component Description & Function” before proceeding.
Disconnect wires to isolate heating element.
Verify 8 ohms +/- 1 for 120 volt heating element.
Verify 28 ohms +/- 1 for 230 volt heating element.
Check from each terminal to ground using at least
a 20M scale. Reading should be infinity.
Replace if fails either test.
Replacement Procedures
Remove service panel.
Disconnect element wires.
Remove clamps & capillary bulb tubing from old element.
Remove the two element lock nuts & remove element.
Install new element & secure with lock nuts.
Reinstall the clamps & capillary tubing onto new element.
Reinstall element wires.
Test unit for proper operation.