Specifications

CCC-20 TECHNICAL MANUAL
LAST UPDATE 5-1-05
1060005 5/05
Component Description & Function
Thermostat: A normally closed (N.C.) capillary bulb style thermostat. The bulb monitors the water temperature. It will
cycle the heating element on & off as needed to maintain water temperature at approximately 162° F (72° C).
Green Light: Used on all CCC-20’s except CCC-20 with Mfg # 9600214. It is a line voltage indicator light that is
located on the head assembly. It is wired in parallel to the thermostat. When lit, it indicates the thermostat contacts are
open & the water temperature should be approximately 162° F (72° C). When not lit, it indicates the thermostat
contacts are closed & calling for heat.
Amber Light: Used ONLY on the CCC-20 with Mfg # 9600214. It is a line voltage indicator light that is located on the
head assembly. It is wired in parallel to the heating element. When lit, it indicates the thermostat contacts are closed &
calling for heat. When not lit, it indicates the thermostat contacts are open & the water temperature should be
approximately 162° F (72° C).
Pan: The main container that accommodates the water, corn baskets, & the head assembly.
Baskets: Wire rack type baskets that accommodate the corn.