Monthly
The Miracle Steamer utilizes an open
steam Generator. Water sprayed onto the
Generator surface ashes into steam im-
mediately, but the minerals in the water
do not steam, they stay on the Generator
surface. A small amount of calcium/mineral
deposits are needed for proper operation,
but a buildup of excessive calcium/mineral
deposits causes poor steaming eciency
and excessive moisture (wet steam), which
will eventually severely hinder the steaming
action.
Cleaning Steam Generator
1. Turn the power o, unplug the
power cord, and allow the unit to
cool down.
2. Perform the Daily cleaning, but do
NOT reassemble the unit.
3. Remove the Wing Nut, Generator
Cover, and Diuser (Figure 11). Wash
these items in hot, soapy water, rinse
and WIPE DRY.
4. With the unit cool, use a wire brush
and/or
scraper to loosen and remove the
excessive calcium/mineral deposits
from the Generator
surface.
5. Take a wire brush and clean out any
buildup from the 28 Steam Ports
(26 vertical and 2 horizontal) of the
Generator (Figure 11). Remove the
loose buildup, wipe the Generator
with a clean, damp cloth, and reas-
semble the unit.
NOTE: If deposits are still excessive and/
or dicult to remove, refer to
Steps 6 and 11.
6. Pour delimer solution (not supplied)
onto the Generator surface. Follow
the delimer manufacturers instruc-
tions for proper mixture and use.
7. Using a sponge or a dry towel, re-
move the delimer solution from the
Generator surface, then rinse with
clean water.
NOTE: To ensure proper steaming
characteristics, some calcium/
mineral deposits must be pres-
ent on the Generator surface. If,
during cleaning, the surface does
become free of calcium/mineral
deposits, add plain tap water to
the surface and allow it to boil
o. If necessary, repeat this pro-
cess to formulate a thin coating
of calcium/mineral deposits.
NOTE: In soft water areas, it may be nec-
essary to add a small amount of
lime to the Generator to season”
it. This will ensure proper steam-
ing characteristics by producing
a thin coating of calcium/min-
eral deposits on the Generator
surface.
Seasoning mixture consists of 3/4
ounces (25ml/ 25cc) baking soda, 3/4
ounces (25ml/25cc) lime mixed with 1 quart
(950ml/950cc) of water. Stir mixture and
pour 1/4” deep onto the hot Generator sur-
face. After mixture is converted to steam,
the remaining loose power can be removed.
8. Plug the power cord into the appro-
priate outlet.
9. Turn the power on and allow the unit
to warm up for approximately 30
minutes.
10. Push and release the Operate
button or the Start/Stop button
several times to operate the steamer.
This purges any remaining delimer
residue from the Generator surface.
11. Turn the power o, reinstall all parts
and accessories, and return the unit
to service.
CAUTION
If a chemical cleaner/delimer is used,
be sure it is safe to use on cast alu-
minum. Observe all precautions and
warnings on the product label.
READY
DIFFUSER
WING NUT
GENERATOR
COVER
Figure 11. Monthly Cleaning
GENERATOR
STEAM PORTS
(26 VERTICAL AND
2 HORIZONTAL)