Operating instructions

MIRACLE STEAMER
10
P/N 1010699 Rev. C
A.J. Antunes & Co.
(Shot Interval Time) in seconds (Item E, Figure
6).
NOTE: 20 seconds is recommended.
7. Depress the program button again and use the
UP or DOWN arrow buttons to change the SHO
(Shot Interval Time) in minutes (Item F, Figure 6).
NOTE: 20 seconds is recommended.
8. Depress the program button again and H
2
O will
be displayed (G, Figure 6).
9. To change the H
2
O (Steam Shot) factory settings
(default), depress the program button again to
display the default setting (Item H, Figure 6). Use
the UP or DOWN arrow buttons to increase or
decrease the time.
NOTE: Recommended settings are:
READY
UP DOWN PROGRAM START/STOP
POWER
1500
Figure 6. Control Programming Sequence
READY
UP DOWN PROGRAM START/STOP
POWER
15
READY
UP DOWN PROGRAM START/STOP
POWER
00
READY
UP DOWN PROGRAM START/STOP
POWER
sho
READY
UP DOWN PROGRAM START/STOP
POWER
00
READY
UP DOWN PROGRAM START/STOP
POWER
20
READY
UP DOWN PROGRAM START/STOP
POWER
H20
READY
UP DOWN PROGRAM START/STOP
POWER
0
70
NOTE: Use the UP or DOWN Arrow Buttons to change the minute or second time interval.
A. Default Setting
B. Total Cycle Minutes
C. Total Cycle Seconds
D. SHO Cycle
E. SHO Time in Seconds
F. SHO Time in Minutes
G. H
2
O Cycle
H. H
2
O Default Setting
MS-250/255 - [0_40] or 0.40 sec (120 VAC)
MS-250/255 - [0_70] or 0.70 sec (208-240 VAC)
MS-150/155/355 - [1_00] or 1.00 sec (208-240 VAC)
10. Press the Start/Stop button to store the changes,
exit the PROGRAM Mode and initiate the cooking
cycle.
NOTE: The Start/Stop button may be pressed at
any time during programming to store the changes
and exit the PROGRAM Mode.
NOTE: If no change is made within 10 seconds
at any time during the programming process, all
changes made up to that point are stored in memo-
ry and the control reverts to the OPERATION Mode.
Steaming Tips