TESTING QUICK DISCONNECT (MALE)
Direct Water Feed Units Only
See Quick Disconnect Male under “Component Description & Function” before proceeding.
Verify the white nylon tip is not chipped, broken, or
damaged.
NOTE: The tip should protrude at least 1/8”.
Verify it retracts when depressed, & protrudes when
released.
NOTE: If water does not flow when the tip is depressed,
it generally indicates there is no water pressure in line.
If the quick disconnect leaks while engaged to the rear of the
unit, the o’ring is worn or damaged & must be replaced.
Replace if fails test
Replacement Procedures
Shut off water line valve that is before the quick disconnect.
Remove clamp & quick disconnect from water line.
Install new quick disconnect & secure with clamp onto water line.
Turn water line valve on & inspect for leaks. Repair if necessary.
Engage the quick disconnect into rear of steamer until a “Click” is
heard.
Operate unit for several cycles to purge air from line.
Test unit for proper operation