Specifications

MS TECHNICAL MANUAL
LAST UPDATE 12-10-04
1060003 12/04
TESTING QUICK DISCONNECT (FEMALE)
Direct Water Feed Units Only
See Quick Disconnect Female under “Component Description & Function” before proceeding
The Female QD is generally trouble free.
If the locking mechanism (Tab, spring, pin) are missing or
damaged, the female QD must be replaced.
Replacement Procedures
Disconnect the solenoid valve wires.
Remove compression nuts & steel tubes from the
brass elbow & “T” fitting.
NOTE: Flexing the Teflon tubes may be required
to ease nut & tube removal.
Remove the two rear female quick disconnect screws.
Remove the solenoid/QD assembly.
Unscrew the QD from the solenoid valve body.
NOTE: Vise may be required.
Thread new QD into the solenoid valve body.
NOTE: Apply thread sealant onto threads & verify
the “IN” & “OUT” on valve.
Reinstall solenoid/QD assembly & secure with screws.
Reinstall the steel tubes, compression nuts, & secure.
Allow unit to preheat 15 minutes.
Run several cycles & check for leaks within electrical
compartment. Repair if needed.
Test unit for proper operation.