Specifications
MS TECHNICAL MANUAL
LAST UPDATE 12-10-04
1060003 12/04
REPLACING SOLENOID VALVE
See Solenoid Valve under “Component Description & Function” before proceeding.
Replacement Procedures
Disconnect solenoid valve wires.
Remove compression nuts & steel tubes from the
brass elbow & “T” fitting.
NOTE: Flexing the Teflon tubes may be required to
ease nut & tube removal.
Remove the two rear female quick disconnect screws.
Remove the solenoid/QD assembly.
Unscrew the QD from the solenoid valve body.
NOTE: Vise may be required.
Thread the QD into the new solenoid valve body.
NOTE: Apply thread sealant onto threads & verify
the “IN” & “OUT” on valve.
Reinstall solenoid/QD assembly & secure with screws.
Reinstall the steel tubes, compression nuts, & secure.
Allow unit to preheat 15 minutes.
Run several cycles & check for leaks within electrical
compartment. Repair if needed.
Test unit for proper operation.