TESTING GENERATOR LID
See Generator Lid under “Component Description & Function” before proceeding.
Ensure the wing nut is tight.
Does noticeable steam leak out the perimeter of the cover?
If yes, remove cover, check it for flatness, & observe its underside.
Does the outer ½” perimeter contain any noticeable calcium buildup?
If yes, replace cover.
NOTE: Calcium buildup at perimeter indicates that steam is
leaking out from there. If perimeter is shiny, it indicates that
steam is not leaking.
NOTE: Gaskets are not used in MS series.
Replacement Procedures
Remove wing nut & lid.
Install new lid & secure with wing nut.
Test unit for proper operation.