Specifications
MS TECHNICAL MANUAL
LAST UPDATE 12-10-04
1060003 12/04
GENERATOR CONTINUED
NOTE: Failure to apply silicone will allow steam to enter the electrical compartment.
Seat new generator in place & secure with new setscrews.
NOTE: Replacement generator will have artificial lime deposits on it that are required for proper
steaming characteristics.
Remove excess silicone & smooth to a neat finish.
Apply Teflon tape to the threads of the Teflon tubes & screw into generator until snug.
Reinstall the steel tubes, compression nuts, & secure.
Reinstall wiring, thermocouple, hi-limit cap tube, brackets, & secure.
Allow unit to heat 15 minutes.
Run several cycles & check for leaks within electrical compartment. Repair if needed.
Reprogram the SHO & H2O settings if needed (See Programming Section).
Reinstall diffuser plate, lid, wing nut, & service panel.
NOTE: Silicone must be allowed to cure 12-24 hours before customer places unit into use.