Specifications

MS TECHNICAL MANUAL
LAST UPDATE 12-10-04
1060003 12/04
TESTING CONTROL BOARD
See Control Board under “Component Description & Function” before proceeding.
TESTING CONTROL BOARD
Control Board must be tested while powered up
(See Technical Theory of Operation).
Check for proper VAC/VDC input & output.
Replace if it fails any of its functions.
Replacement Procedures
Disconnect control board wiring & unplug thermocouple
(Mark for reinstallation).
Remove the nuts & the control board.
Install new control board & secure with the nuts.
Reinstall the wiring & thermocouple onto control board.
Allow unit to heat up 15 minutes.
You must Program the control board per instruction sheet
(Included in kit) # 1010849.
NOTE: Failure to program upon install may result in
improper operation.
Test unit for proper operation.