Specifications
Project No.:ZKT-211130L6532E
Page 28 of 38
Polar
(H/V)
Frequency
Meter
Reading
Pre-ampli
fier
Cable
Loss
Antenna
Factor
Emission
Level
Limits
Margin
Detector
Type
(MHz)
(dBuV)
(dB)
(dB)
(dB)
(dBuV/m)
(dBuV/m)
(dB)
High Channel:2480MHz
V
4960.00
50.60
30.55
5.77
31.79
57.61
74.00
-16.39
Pk
V
4960.00
31.80
30.55
5.77
31.79
38.81
54.00
-15.19
AV
V
7440.00
52.84
30.33
6.32
36.38
65.21
74.00
-8.79
Pk
V
7440.00
32.52
30.33
6.32
36.38
44.89
54.00
-9.11
AV
V
9920.00
52.94
30.85
7.45
36.50
66.04
74.00
-7.96
Pk
V
9920.00
32.74
30.85
7.45
36.50
45.84
54.00
-8.16
AV
V
12400.00
52.84
31.02
8.99
39.11
69.92
74.00
-4.08
Pk
V
12400.00
32.08
31.02
8.99
39.11
49.16
54.00
-4.84
AV
H
4960.00
50.62
30.55
5.77
31.79
57.63
74.00
-16.37
Pk
H
4960.00
32.29
30.55
5.77
31.79
39.30
54.00
-14.70
AV
H
7440.00
52.11
30.33
6.32
36.38
64.48
74.00
-9.52
Pk
H
7440.00
32.75
30.33
6.32
36.38
45.12
54.00
-8.88
AV
H
9920.00
52.81
30.85
7.45
36.50
65.91
74.00
-8.09
Pk
H
9920.00
33.14
30.85
7.45
36.50
46.24
54.00
-7.76
AV
H
12400.00
52.71
31.02
8.99
39.11
69.79
74.00
-4.21
Pk
H
12400.00
32.65
31.02
8.99
39.11
49.73
54.00
-4.27
AV
Remark:
1. Emission Level = Meter Reading + Antenna Factor + Cable Loss – Pre-amplifier,
Margin= Emission Level - Limit
2. If peak below the average limit, the average emission was no test.
3. The amplitude of spurious emissions which are attenuated by more than 20dB below the permissible value
has no need to be reported.