Owner`s manual

2
FEATURES
1. Microprocessor Fuel Computer - Accuratelymonitorsthe
energyinthebatterywithprogramsthattakeintoaccount
batteryage,selfdischarge,charge/dischargerate,operat-
ingconditionsandpreviouslyexperiencedcharge/discharge
cycles.TheDIONIC
®
HCbatteryconstantly“learns”its
precisestateofchargeandremainingcapacity.Thisdatais
automaticallytransmittedtoanInterActivecharger.
2. Integral RealTime ‘LCD’ – ThisnewandexclusiveAnton/
Bauerfeaturedisplaysboththeremainingruntimeandthe
percentageofremainingbatterycapacityatalltimes- si-
multaneously
.Nospecialadaptersorsetupisrequired.(see
completeexplanationpage3)
3. Viewnder Fuel Gauge Display - Cameraswhichincludethe
Anton/BauerInterActiveviewnderfeatureconnectwiththe
DIONIC
®
HCbattery“FuelComputer”todisplayanaccurate
“FuelGauge”ofremainingbatterycapacityintheviewnder.
Referenceyourcamera/camcordersowner’smanualfor
propermenusettings.
4. Impac
®
Case design - Highimpactcaseconstruction
protectsthecellsfromimpactthatwoulddamageordestroy
conventionalbatteries.
5. Gold Mount
®
Interface - PatentedworldwidestandardGold
MountconnectoriscompatiblewithallAnton/Bauercamera
mountsandaccessories.
6. Individual Computer Testing – AswithallAnton/Bauer
batteries,eachandeveryDIONIC®HCbatteryisindividually
testedtoassureoptimumcapacity,voltageandoverallqual-
ity.Aserializedcomputerperformancegraphasconrmation
ofthistestingisenclosed.
CHARGING DIONIC HC BATTERIES
• DONOTATTEMPTTOCHARGETHISBATTERYWITHANYCHAR-
GEROTHERTHANTHEANTON/BAUERInterActiveORTSERIES
CHARGERSSPECIFIEDINTHISMANUAL.
Allow the battery to reach a steady green (LifeSaver
®
) mode
before using for the rst time. Please read the individual charger
Owner’s Manual to become acquainted with the many unique
operating features of the chargers.
•
TheDIONIC®HCbatterywillbeapproximately90%chargedwhenthe
LED’sonthechargerindicateFLASHINGGREEN.Thebatteryis100%
chargedwhenthechargerindicatesSTEADYGREEN.TheDionicHC
batterymayberemovedfromthechargeranddischargedineither
condition.
• The DIONIC
®
HC battery can remain on the charger until just prior
to being used.
TheLifeSaver(STEADYGREENchargerLEDindica-
tion)maintenanceroutinekeepsthebatterychargedandreadyfor
use.Ifthebatterywillnotbeusedforanextendedperiod(morethan
60days)see“OperatingGuidelines”onpage4.
ForbestresultsthisbatteryshouldbeusedorreturnedtotheInterAc-
tiveorTSerieschargerwithin48hoursofbeingused.
Note:Onsomeolderchargersitmaybenecessarytoinstallbatteryon
charger,waitone(1)minute,thenremovebatteryandre-install.This
proceduremayneedtoberepeatedmorethanonceto“wakeup”alow
voltagebattery.
NOMINAL CHARGE TIMES FOR DIONIC® HC
Charge Level LED Indicators
90%
Flashing
Green
100%
Steady
Green
Dual 2722 (2 batteries simultaneously) 2hrs. 3hrs.
InterActive PowerCharger
(Quad/Dual – 2702/2701/2700)
(Quad/Dual – 2401/2400)
(2 or 4 batteries sequentially)
2 hrs. 3 hrs.
T2 (2 batteries simultaneously) 2hrs. 3hrs.
Tandem
®
70 2hrs. 3hrs.
TWIN (2 batteries simultaneously) 4hrs. 5hrs.
TWQ (4 batteries simultaneously) 4hrs. 5hrs.
TM-4 (4 batteries simultaneously) 2hrs. 3hrs.
Chargetimecanvarydependingonage,conditionandremainingcapacityofeach
batteryatthetimeitisplacedonthecharger.
CHARGING TIMES
Approved Copy