GUIDELINES FOR OPTIMUM PERFORMANCE AND MAX LIFE
1. Keepbatteriescooloratroomtemperatureswheneverpossible.Sustainedelevatedtemperaturesaretheprimaryreasonfor
prematurefailureofNiCadbatteries:
• Charging -Chargebatteriesatroomtemperature.Inwarmclimateskeepchargersinairconditionedroomsthatare
maintainedbetween65°Fto85°Fforbestperformance.
• On assignment -Donotleavebatteriesinahotvehicletrunkoroutindirectsunlightunnecessarily.
• Storage -Ifbatteriesarenotgoingtobeusedforseveralmonths,theyshouldbefullydischarged,sealedinaplasticbag
andstoredinarefrigeratororfreezer.
2. UseonlyAnton/BauerLogicSeries
®
Lifesaver
®
Chargersandkeepbatteriesonthechargeruntiljustpriortobeingused.
3. ReturnbatteriestotheLogicSeries
®
Chargerassoonaspossibleafteruse,preferablywithin24hours.
4. Donotover-dischargebatteries-ItisquitepropertodischargeabatteryuntilalowvoltagewarninginthecameraorVTRisob-
served.However,aswitchtoafreshbatteryshouldoccurassoonaspossiblefollowingsuchindication.
• ADIGITALbatteryshouldbechangedassoonaspossibleaftera"Flashing15minutesegment"isindicated.Nevercon-
tinuetouseaDIGITALbatteryafterthe“Flashing15minutesegment”hasappeared.
• Neverleaveabatteryoperateddeviceunattendedwhileitisrunning.
5. Dischargingthebatteryfordiagnosticpurposesshouldonlybeperformedonanoccasionalbasis(onceevery6-8weeksatmost).
Unnecessarydischargingonlydetractsfromoveralllife.
6. Periodiccleaningofboththechargerterminalsandbatteryterminalswillensurecontinuedreliableoperation.Dirtyterminals
maycausethebatterytoindicateasteadyred(“Hold”)modeonthecharger.Cleaningtheterminalswithapencileraserorlightly
scrapingthesurfacewithabluntinstrumentwillhelpreducethissituation.Anton/Bauerpublishesacomprehensive“VideoBat-
teryHandbook”tohelpyoufurthermaximizethelifeandperformanceofyournewDIGITALbattery.Thisguideisavailableatno
chargebycontactingAnton/Bauerat1-800-422-3473or203-929-1100orfax203-929-9935.