Connector mapping
Signals
Description
Type
Nbr of lines
Max voltage
External ID
lines
Used to
identify which
type of device
the COPA
mesh module
is connected
to.
DIO
3
(Low/High
level
identification
on each line)
VDDS+0.3V (max
4.1V)
GPIOs
General
purpose
inputs/outputs
DIO
6
VDDS+0.3V (max
4.1V)
Button
Interface
Low level if
button
pressed,
VDDS if not
pressed
DIO
1
VDDS+0.3V (max
4.1V)
VEXT_SENSE
ADC input to
detect
presence and
level of
external
supply
Analog
input
1
-0.3V to VDDS
(see CC1312R
datasheet)
VEXT_ON
External
power sense
DIO
1
VDDS+0.3V (max
4.1V)
External
power supply
pins
Input pins for
external
power supply.
Voltage
input
2
3.4V in order not to
back charge the
COPA mesh board
battery in case of
hardware failure.