Installation manual

Engineering - 38
Output Wiring
Of the four outputs on the 8x4 Switcher, only two are needed. Output 1 is routed to an input on the
console, and output 2 is routed to the record inputs of the SMARTCASTER.
8x4 Switcher output wiring.
Unbalanced feeds are connected with the center conductor wired to the ‘+’ terminal, and the shield
connected to Ground. The ‘-‘ terminal is not used with unbalanced connections. For balanced
connections, the Ground terminal is provided if needed. However, take care not to Ground the shield at
both ends of the cable.
If the SMARTCASTER is using a dBX, connect output 2 of the 8x4 Switcher through the dBX into the
record inputs of the SMARTCASTER. If there is not a dBX, then connect output 2 directly to the record
inputs of the SMARTCASTER.