User Manual

12
Maximum shock
withstanding Non-operating, ight case mounted:
100m/s
2
(~10.2 g*), 11 msec half-sine pulse per IEC 60068-2-27:2008
Non-operating, in original packing:
300m/s
2
(~30.6 g*), 5 msec half-sine pulse per IEC 60068-2-27:2008
* g – gravitational acceleration
Power Supply Type: AC
Power Supply Input: 100 – 240 V~
Power Consumption: 15 W
Atomic Clock Outputs: 10 x BNC Sinusoidal, 10MHZ, 75 Ohm, 1Vpp typical (unloaded)
Outputs: Word Clock: 4 x BNC
AES/EBU: 2 x XLR
S/PDIF: 2 x RCA
USB: USB 2.0 Full-Speed, Type B, only for control
Word Clock Specs TTL Level, 75 Ohm Output Impedance
Operating Temperature: 0 – 50°C, 32-122 F
Humidity: 30 – 80% RH non-condensing
Dimensions: 482.6 (W) х228 (D) х 44 (H) mm
19 (W) x 9 (D) x 1.73 (H) inch
Weight: 2.8 kg/6.17 lb
10. Antelope Audio Support Resources
Antelope Audio offers a range of services and support resources for your Antelope hardware,
rmware and software control panels.
FAQ
Several categories of frequently asked questions are available on the website:
http://www.antelopeaudio.com/en/support
Telephone Support
Phone line is for general inquiries and technical support: +1 734 418 8661
Hours of Operation: 7:00 a.m. - 3:00 p.m. (EST)
Help Desk
A ticketing system ensures a 24-hour response time:
www.antelopeaudio.com/en/support/help-desk