NEOPOWER 380/480 User’s Manual Manuel de l’utilisateur Anwenderhandbuch Manuale per l’operatore Manual del usuario
ATX12V v2.0 Power Supply Includes Universal Input and Active Power Factor Correction (PFC) crashes and you can't shut it down using the soft switch, you can switch the main power to the OFF (O) position. Models: NEO380 and NEO480 Advanced Cable Management System – NeoPower features Antec's advanced Cable Management System. It allows you to use only the power cables that you need, thereby reducing clutter and improving airflow inside your case.
Installing NeoPower 1. Disconnect the power cord from your old power supply. 2. Open your computer case. Follow the directions provided in your case manual. 3. Disconnect all the power connectors from the motherboard and from the peripheral devices such as case fans, hard drives, floppy drives, etc. 4. Remove the existing power supply from your computer case and replace it with the NeoPower power supply. 5. Connect the 24-pin Main Power Connector and the 4-pin +12V Connector to your motherboard as needed.
Quantity 1 Description Part name includes 24-pin main connector, 4-pin 12V connector, and 3-pin fan monitoring connector with cable installed NEO power supply 1 Molex connector w/ 47 cm cable includes three Molex connectors 2 Molex connector w/ 77 cm cable includes three Molex connectors 1 77 cm Serial ATA connector w/cable includes two Serial ATA connectors 1 40 cm Fan-Only Connector w/cable includes two Fan-only connectors 1 14 cm Molex to Floppy connectors w/cable includes one Molex an
has been removed and reset PS-ON for a minimum of 1 second. Then it will turn on again. 115V/230V(FULL LOAD):1mS minimum 3.1 OVER CURRENT PROTECTION +5V Over current (Sense level) +12V1 &+12V2 AC-V +3.3V NEO380 40A Min. 52A Max. 19A Min. 26A Max. 34A Min. 45A Max. NEO480 44A Min. 56A Max. 24A Min. 26A max. 36A Min. 47A Max. AC-O N AC-O FF 3.2 OVER VOLTAGE PROTECTION Sense level +12V1&+12V2 H IGH Over Voltage 13.3V Min. H IGH PS-O N LO W VB =4.75V 14.3V Max. +5V 5.7V Min. 6.2V Max.
5.0 5.1 5.2 5.3 5.4 ENVIRONMENT: Ambient Operation temperature 0°C to +50°C Ambient operation relative humidity 20% to 85% Ambient storage temperature -40°C to +70° C Ambient storage relative humidity 10% to 95% 6.0 CE REQUIREMENTS: 6.1 EMI Meets FCC PART15 CLASS B 6.2 SAFETY REQUIREMENTS Meets UL 1950, Third Edition Meets EN 60950:1992 +A1:1993 +A2:1993 +A3:1995 +A4:1997 +A11:1997 Meets IEC 60950:1991 +A1:1992 +A2:1993 +A3:1995 +A4:1996 7.0 MTBF: 80,000 hours at 25°C (demonstrated) 8.