M-7 Stage Fog Machine User Manual English © 2014 Antari Lighting and Effects Ltd.
Safety Information Please read the following safety information carefully before operating the machine. Information includes important safety information about installation, usage, and maintenance. Pay attention to all warning labels and instructions in this manual and printed on the machine. If you have questions about how to operate the machine safely, please contact your local Antari dealer for help. ․ Keep this device dry. ․ Always connect to a grounded circuit to avoid risk of electrocution.
Unpacking and Inspection Immediately upon receiving the machine, carefully unpack the carton, check all content to ensure that all parts are present and have been received in good condition. If any parts appear damaged or mishandled from shipping, notify the shipper immediately and retrain the packing material for inspection. What is included: 1 x M-7 Fogger 1 x W-2 Wireless Remote 1 x Power Cord 1 x User Manual Product Dimension 385.
Setting Up Step 1: Place the machine on a flat surface and in a suitable large area with at least 50 cm open space around the machine. Step 2: Fill the fluid tank with Antari approved fluid. Step 3: Connect the machine to suitable rated power supply. To determine the power requirement for the machine refer to the label on the back of the machine. Always connect the machine to a protected circuit and ensure it is properly grounded to avoid risk of electrocution.
Button Function [MENU] Scroll through setting menu ▲ [UP]/[TIMER] Up/Activate Timer function ▼ [DOWN]/[VOLUME] Down/Activate Volume function [STOP] Deactivate Timer/Volume function Control Menu DMX512 Address: 1 Set DMX address from 1 to 504 Stand Alone Set Master Color Mode On Set machine as Master of Slave unit Turn LED On or Off Color Mode Marco:01 Set LED output color from macro 1 to 10 Color Mode Chase:01 Timer Set LED chase from 1 to 15 Set interval from 15 to 360 seconds Interval
Wireless Setting Set wireless remote button function macro color 1 to 10 or chase Button A:M01 1 to 15 and off. Set wireless remote button function macro color 1 to 10 or chase Wireless Setting Button B:M01 Wireless Setting 1 to 15 and off. Set wireless remote button function macro color 1 to 10 or chase Button C:M01 Wireless Setting 1 to 15 and off. Set wireless remote button function macro color 1 to 10 or Button D:M01 chase 1 to 15 and off.
W-2 Wireless Transmitter Wireless Receiver Wireless settings are configurable through onboard control panel, refer to control menu section to setup each buttons. In a free open space the effective distance is 50 meters, actual usage depending on obstacle level the effective distance is 10-25 meters. Registering transmitter Transmitter can be pair or deleted from the receiver. Each receiver can pair up to 10 transmitters. Follow below steps to pair or delete transmitter from receiver.
Transmitter battery replacement If effective distance seems to be decreased, it is possible the battery level are low and require replacement. In order to replace the battery, undo the three screws on the back of transmitter to release the cover. Replace with same type and specification of battery which is 27A 12V DMX Connector Pin Assignment The machine provide 3 or 5 pin XLR connector for DMX connection.
Channel 3 DMX Value Range Function Green LED 0-255 0-100% Channel 4 DMX Value Range Function Blue LED 0-255 0-100% Channel 5 DMX Value Range Function Chase 1-15 Chase 1 16-31 Chase 2 32-47 Chase 3 48-63 Chase 4 64-79 Chase 5 80-95 Chase 6 96-111 Chase 7 112-127 Chase 8 128-143 Chase 9 144-159 Chase 10 160-175 Chase 11 176-191 Chase 12 192-207 Chase 13 208-223 Chase 14 224-255 Chase 15 Channel 6 DMX Value Range Function Chase Speed 0-255 0-255 step per min
malfunction. Service and Maintenance ․ Do not allow the machine to become contaminated. ․ Remove dust from air vents with air compressor, vacuum or a soft brush. ․ Only use a damp cloth to clean the casing. ․ Before storing run distilled water through the system to help avoid condensing the pump or heater. ․ It is recommended to run the machine on a monthly basis in order to achieve best performance and output condition.
Technical Specifications Input voltage 120V 60Hz or 230V 50Hz Breaker 120V = 15A 250V 230V = 9A 250V Heater 1550W Warm-up time 5 min. (approx.) Coverage volume Height 5 Meters, Width 1 Meter Max. operating time 8 seconds burst Fluid tank capacity 2.4 L Fluid consumption 25 ml/10 sec.
C08M07000 12