User manual

and must be replaced. For this purpose, take off the housing cover and remove
the used battery. Insert a fresh 12 V battery, type 23A as indicated in the
battery compartment and refit the housing cover.
W-510 DMX512 Fog Machine Settings
Channel A
0 - 5 = off (no output)
6 - 255 = maximum volume (100 % output)
Model W-510 has on-board DMX control, model W-508 does not. Addressing is
via DIP switches. W-510 uses 1 channel to control on/off operation. The
channel has a value range of 0 to 255. The on/off function can also be
programmed with a DMX controller or a DMX control software used by the
lighting and effects operator.
If channel A has a value from 0 to 5, the unit is off.
Between the values 6 to 255 the machine has a maximum output volume
of 100 %.
Note: If, for example, the machine is assigned to the DMX address 130, channel
A corresponds to DMX address 130.
Addressing
Each machine occupies 1 channel. To ensure that the control signals are
properly directed to the machine, it requires addressing. If several machines
are used, each machine must be addressed by changing the DIP switches as set
out in the table below.
The starting address is defined as the first channel from which the machine will
respond to the controller.