Application Guide

[78]
Software User's
Manual
Version 3.0
Ethernet Type
Only Ethernet Type frames can match this ACE. The IEEE 802.3
describes the value of Length/Type Field specifications to be greater
than or equal to 1536 decimal (equal to 0600 hexadecimal) and the
value should not be equal to 0x800(IPv4), 0x806(ARP), or
0x86DD(IPv6).
ARP
Only ARP frames can match this ACE. Notice the ARP frames won’t
match the ACE with
E
thernet type.
IPv4
Only IPv4 frames can match this ACE. Notice the IPv4 frames won’t
match the ACE with
E
thernet
type.
IPv6
Only IPv6 frames can match this ACE. Notice the IPv6 frames won’t
match the ACE with Ethernet type.
Action
Specify the action to take with a frame that hits this ACE.
Setting Description
Factory
Default
Permit
The frame that hits this ACE is granted permission for the ACE
operation.
Permit
Deny The frame that hits this ACE is dropped.
Filter Frames matching the ACE are filtered.
Rate Limiter
Specify the rate limiter in number of base units.
Setting Description
Factory
Default
Disabled Rate limiter operation is disabled.
Disabled
1~16
Specify the rate limiter in number of base units. The allowed range is
1 to 16.
Port Redirect
Frames that hit the ACE are redirected to the port number specified here. The rate limiter will affect
these ports. The allowed range is the same as the switch port number range. Disabled indicates that
the port redirect operation is disabled and the specific port number of 'Port Redirect' can't be set when
action is permitted.
Setting Description
Factory
Default
Disabled Port redirect operation is disabled.
Disabled
Enabled Port redirect operation is enabled.
Mirror
Specify the mirror operation of this port. Frames matching the ACE are mirrored to the destination
mirror port. The rate limiter will not affect frames on the mirror port.
Setting Description
Factory
Default
Enabled Frames received on the port are mirrored.
Disabled