Application Guide
[62]
Software User's
Manual
–
Version 3.0
disconnected and reconnected on the port (by disconnecting the cable), the
port will remain shut down. There are three ways to re-open the port:
1. Boot the switch,
2. Disable and re-enable Limit Control on the port or the switch,
3. Click the Reopen button.
Trap & Shutdown: If Limit + 1 MAC addresses are seen on the port, both the
Trap and the Shutdown actions described above will be taken.
State
This column shows the current state of the port as seen from the Limit
Control’s point of view. The state takes one of four values:
Disabled: Limit Control is either globally disabled or disabled on the port.
Ready: The limit is not yet reached. This can be shown for all actions.
Limit Reached: Indicates that the limit is reached on this port. This state can
only be shown if Action is set to None or Trap.
Shutdown: Indicates that the port is shut down by the Limit Control module.
This state can only be shown if Action is set to Shutdown or Trap &
Shutdown.
Re-open Button
If a port is shutdown by this module, you may reopen it by clicking this button,
which will only be enabled if this is the case. For other methods, refer to
Shutdown in the Action section.
Note that clicking the reopen button causes the page to be refreshed, so non-
committed changes will be lost.