OutQLen: The length of the output packet queue (in packets).
Sample Type
The method of sampling the selected variable and calculating the value to be
compared against the thresholds, possible sample types are:
Absolute: Get the sample directly.
Delta: Calculate the difference between samples (default).
Value The value of the statistic during the last sampling period.
Startup Alarm
The method of sampling the selected variable and calculating the value to be
compared against the thresholds, possible sample types are:
Rising: Trigger alarm when the first value is larger than the rising
threshold.
Falling: Trigger alarm when the first value is less than the falling
threshold.
RisingOrFalling: Trigger alarm when the first value is larger than the
rising threshold or less than the falling threshold (default).
Rising
Threshold
Rising threshold value (-2147483648-2147483647).
Rising Index Rising event index (1-65535).
Falling
Threshold
Falling threshold value (-2147483648-2147483647).
Falling Index Falling event index (1-65535).